Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
1.
Pract Lab Med ; 39: e00392, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38617587

RESUMO

Objectives: Coronavirus disease 2019 (COVID-19) has a wide spectrum of clinical severity. A cytokine storm is associated with COVID-19 severity. Of these, IL-6 is significantly associated with higher mortality and is also a marker for predicting disease prognosis. IL-6 may act as a target for therapeutics and, a blockade of IL-6 function by Tocilizumab has been described as a treatment of the inflammatory process COVID-19-related. This study aims to describe our experience comparing two different methods, in detail Human IL-6 Instant ELISA and the Elecsys IL-6 based on ECLIA, for the IL-6 assessment. Design and methods: IL-6 levels from serum samples of 104 COVID-19 patients, admitted to the AOU Careggi (Hospital in Florence -Italy), were assessed by using the two above-mentioned methods, and the results were analysed through Passing-Bablok regression fit and Bland-Altman plot. Results: The regression exhibited a linear relation between the methods with a regression equation (y = - 0.13 + 0.63 x; 95 % C.I. intercept = - 0.13 to 4.55; 95 % C.I. slope = 1.03 to 1.26 with R2 = 0.89, p > 0.05), showing a positive slope. The agreement of the two methods reported a bias of -25.0 pg/mL. Thus, the two methods correlate but do not agree in terms of numeric results. Conclusions: The two assays showed good comparability. However, because of the extremely wide linear range of the ECLIA, its throughput and its capacity for immune profiling, it represents an interesting emerging technology in the immunology field.

2.
Arh Hig Rada Toksikol ; 75(1): 41-50, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38548384

RESUMO

Healthcare workers handling antineoplastic drugs (ADs) in preparation units run the risk of occupational exposure to contaminated surfaces and associated mutagenic, teratogenic, and oncogenic effects of those drugs. To minimise this risk, automated compounding systems, mainly robots, have been replacing manual preparation of intravenous drugs for the last 20 years now, and their number is on the rise. To evaluate contamination risk and the quality of the working environment for healthcare workers preparing ADs, we applied the Failure Mode Effects and Criticality Analysis (FMECA) method to compare the acceptable risk level (ARL), based on the risk priority number (RPN) calculated from five identified failure modes, with the measured risk level (MRL). The model has shown higher risk of exposure with powdered ADs and containers not protected by external plastic shrink film, but we found no clear difference in contamination risk between manual and automated preparation. This approach could be useful to assess and prevent the risk of occupational exposure for healthcare workers coming from residual cytotoxic contamination both for current handling procedures and the newly designed ones. At the same time, contamination monitoring data can be used to keep track of the quality of working conditions by comparing the observed risk profiles with the proposed ARL. Our study has shown that automated preparation may have an upper hand in terms of safety but still leaves room for improvement, at least in our four hospitals.


Assuntos
Antineoplásicos , Exposição Ocupacional , Humanos , Setor de Assistência à Saúde , Antineoplásicos/análise , Exposição Ocupacional/efeitos adversos , Exposição Ocupacional/prevenção & controle , Exposição Ocupacional/análise , Hospitais , Pessoal de Saúde , Monitoramento Ambiental/métodos
3.
Molecules ; 29(3)2024 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-38338382

RESUMO

Despite the considerable steps taken in the last decade in the context of antineoplastic drug (AD) handling procedures, their mutagenic effect still poses a threat to healthcare personnel actively involved in compounding and administration units. Biological monitoring procedures usually require large volumes of sample and extraction solvents, or do not provide adequate sensitivity. It is here proposed a fast and automated method to evaluate the urinary levels of cyclophosphamide and iphosphamide, composed of a miniaturized solid phase extraction (µSPE) followed by ultrahigh-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) analysis. The extraction procedure, developed through design of experiments (DoE) on the ePrep One Workstation, required a total time of 9.5 min per sample, with recoveries of 77-79% and a solvent consumption lower than 1.5 mL per 1 mL of urine sample. Thanks to the UHPLC-MS/MS method, the limits of quantification (LOQ) obtained were lower than 10 pg/mL. The analytical procedure was successfully applied to 23 urine samples from compounding wards of four Italian hospitals, which resulted in contaminations between 27 and 182 pg/mL.


Assuntos
Antineoplásicos , Exposição Ocupacional , Ifosfamida , Espectrometria de Massas em Tandem/métodos , Espectrometria de Massa com Cromatografia Líquida , Monitoramento Biológico , Ciclofosfamida , Cromatografia Líquida de Alta Pressão/métodos , Extração em Fase Sólida , Solventes
4.
Arh Hig Rada Toksikol ; 74(3): 187-197, 2023 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-37791676

RESUMO

Antineoplastic drugs (ADs) are essential tools in cancer treatment, but their cytotoxicity poses a risk to workers involved in their handling. In a hospital environment fundamental strategies for minimising exposure involve proper use of safety cabinets and closed-circuit transfer devices, along with personnel training and increased awareness of risks. However, medical gloves remain the first line of defence. In this respect the evaluation of glove materials and best choices can improve hospital safety management and prevent potential hazards and long-term consequences. The aim of this study was to assess contamination of gloves in samples taken from AD administration and preparation units of nine Italian hospitals and to raise awareness of the importance of evaluating chemico-physical properties of gloves. Our findings show that 33 % of the analysed gloves were positive for at least one AD, with contaminations ranging from 0.6 to 20,729 pg/ cm2. We proposed the alert glove values (AGVs) for each AD as a limit value for contamination assessment and good practice evaluation. Our findings also point to multiple AD contamination (43 % of positive findings in preparation units), calculated as total AGV (AGV-T), and confirm that gloves should be replaced after 30 min of AD handling, based on cumulative permeation and area under the curve (AUC), to maintain safety and limit dermal exposure.


Assuntos
Antineoplásicos , Exposição Ocupacional , Humanos , Setor de Assistência à Saúde , Antineoplásicos/efeitos adversos , Exposição Ocupacional/prevenção & controle , Exposição Ocupacional/análise , Hospitais , Luvas Protetoras
5.
Molecules ; 28(14)2023 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-37513313

RESUMO

Formaldehyde (FA) is a toxic compound and a human carcinogen. Regulating FA-releasing substances in commercial goods is a growing and interesting topic: worldwide production sectors, like food industries, textiles, wood manufacture, and cosmetics, are involved. Thus, there is a need for sensitive, economical, and specific FA monitoring tools. Solid-phase microextraction (SPME), with O-(2,3,4,5,6-pentafluorobenzyl)-hydroxylamine (PFBHA) on-sample derivatization and gas chromatography, is proposed for FA monitoring of real-life samples. This study reports the use of polydimethylsiloxane (PDMS) as a sorbent phase combined with innovative commercial methods, such as multiple SPME (MSPME) and cooling-assisted SPME, for FA determination. Critical steps, such as extraction and sampling, were evaluated in method development. The derivatization was performed at 60 °C for 30 min, followed by 15 min sampling at 10 °C, in three cycles (SPME Arrow) or six cycles (SPME). The sensitivity was satisfactory for the method's purposes (LOD-LOQ at 11-36 ng L-1, and 8-26 ng L-1, for SPME and SPME Arrow, respectively). The method's linearity ranges from the lower LOQ at trace level (ng L-1) to the upper LOQ at 40 mg L-1. The precision range was 5.7-10.2% and 4.8-9.6% and the accuracy was 97.4% and 96.3% for SPME and SPME Arrow, respectively. The cooling MSPME set-up applied to real commercial goods provided results of quality comparable to previously published data.

6.
ACS Omega ; 8(17): 15397-15405, 2023 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-37151501

RESUMO

Trimellitic, phthalic, and maleic anhydrides are important building blocks to produce polymers and additives, such as plasticizers. In humans, the exposure to these compounds can cause several health issues. In European Union and USA, their presence in substances and mixtures is restricted by CLP Regulation (no. 1272/2008) and HCS/HazCom 2012, respectively, but no information about the corresponding acids is reported. For this reason, a selective method to determine anhydrides in mixtures, in the presence of acids, could be interesting. Nowadays, methods in the literature are either not selective or use explosive and toxic reagents (as diazomethane). In this work, an innovative, greener, and safer method for the simultaneous recognition and quantification of anhydrides and acids, via direct injection gas chromatography-mass spectrometry, is developed. The sample pretreatment consists in selective esterification with absolute ethanol on the anhydride, followed by a treatment with boron trifluoride-methanol for the methylation of remaining carboxylic groups. The optimization of the functionalization, a crucial step of the method, was optimized by experimental design. The limit of detection-limit of quantification (LOD-LOQ) values for trimellitic, phthalic, and maleic anhydrides are 0.31-0.93, 0.47-1.41, and 0.06-0.18 µg/mL, respectively.

7.
Int J Mol Sci ; 24(3)2023 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-36768368

RESUMO

Studies have indicated that air pollution, including surface-level ozone (O3), can significantly influence the risk of chronic diseases. To better understand the carcinogenic mechanisms of air pollutants and identify predictive disease biomarkers, we examined the association between traffic-related pollutants with DNA methylation alterations and bulky DNA adducts, two biomarkers of carcinogen exposure and cancer risk, in the peripheral blood of 140 volunteers-95 traffic police officers, and 45 unexposed subjects. The DNA methylation and adduct measurements were performed by bisulfite-PCR and pyrosequencing and 32P-postlabeling assay. Airborne levels of benzo(a)pyrene [B(a)P], carbon monoxide, and tropospheric O3 were determined by personal exposure biomonitoring or by fixed monitoring stations. Overall, air pollution exposure was associated with a significant reduction (1.41 units) in global DNA methylation (95% C.I. -2.65-0.04, p = 0.026). The decrement in ALU repetitive elements was greatest in the policemen working downtown (95% C.I. -3.23--0.49, p = 0.008). The DNA adducts were found to be significantly increased (0.45 units) in the municipal officers with respect to unexposed subjects (95% C.I. 0.02-0.88, p = 0.039), mainly in those who were controlling traffic in downtown areas (95% C.I. 0.39-1.29, p < 0.001). Regression models indicated an increment of ALU methylation at higher B(a)P concentrations (95% C.I. 0.03-0.60, p = 0.032). Moreover, statistical models showed a decrement in ALU methylation and an increment of DNA damage only above the cut-off value of 30 µg/m3 O3. A significant increment of 0.73 units of IL-6 gene methylation was also found in smokers with respect to non-smokers. Our results highlighted the role of air pollution on epigenetic alterations and genotoxic effects, especially above the target value of 30 µg/m3 surface-level O3, supporting the necessity for developing public health strategies aimed to reduce traffic-related air pollution molecular alterations.


Assuntos
Poluentes Atmosféricos , Poluição do Ar , Ozônio , Humanos , Adutos de DNA/genética , Ozônio/toxicidade , Dano ao DNA , Poluentes Atmosféricos/toxicidade , Poluentes Atmosféricos/análise , Poluição do Ar/efeitos adversos , Poluição do Ar/análise , Biomarcadores
8.
Med Pr ; 73(5): 383-396, 2022 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-36374172

RESUMO

BACKGROUND: Chemotherapy drugs are widely used to treat cancer, but their active compounds represent a danger for workers who could be exposed to them. However, they aren't yet included in directive CE No. 1272/2008 and the European Biosafety Network has only recommended a limit value of 100 pg/cm2 for surface contamination. Thus, it is crucial to assess surface contaminations in healthcare environments. Currently, the technique of choice is surface wipe test combined with liquid chromatography tandem mass spectrometry to achieve high sensibility. MATERIAL AND METHODS: A campaign involving Careggi University Hospital (Florence, Italy) was performed from January 2020 to December 2021, collecting 1449 wipe samples between administration units, preparation unit, and personnel gloves. From the obtained data, the 90th percentile was calculated for 30 antiblastic drugs and proposed as surface exposure levels (SELs); while from data concerning personnel glove contamination, weekly contamination was estimated. RESULTS: In the 2-year period only 417 wipe samples were found positive (28.8%), the majority of which regard samples coming from administration unit bathrooms. The proposed SELs are almost all <100 pg/cm2, except for few drugs which produce higher contamination on bathroom surfaces. Also, the estimation of pharmacy personnel's glove contamination highlighted very low results (ng/week). CONCLUSIONS: Deeply established protocols and procedures for safe handling of ADs allow for obtaining excellent cleaning results and thus a safer work environment, however, the risk of cytostatic contaminations cannot be avoided in healthcare workplaces, and thus a harmonization of classification and labeling of chemotherapy drugs throughout the European Union should be done. Med Pr. 2022;73(5):383-96.


Assuntos
Antineoplásicos , Exposição Ocupacional , Humanos , Exposição Ocupacional/prevenção & controle , Exposição Ocupacional/análise , Monitoramento Ambiental/métodos , Antineoplásicos/análise , Cromatografia Líquida , Local de Trabalho , Contaminação de Equipamentos
9.
J Anal Methods Chem ; 2022: 8690569, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35154846

RESUMO

The solid-phase microextraction (SPME), invented by Pawliszyn in 1989, today has a renewed and growing use and interest in the scientific community with fourteen techniques currently available on the market. The miniaturization of traditional sample preparation devices fulfills the new request of an environmental friendly analytical chemistry. The recent upswing of these solid-phase microextraction technologies has brought new availability and range of robotic automation. The microextraction solutions propose today on the market can cover a wide variety of analytical fields and applications. This review reports on the state-of-the-art innovative solid-phase microextraction techniques, especially those used for chromatographic separation and mass-spectrometric detection, given the recent improvements in availability and range of automation techniques. The progressively implemented solid-phase microextraction techniques and related automated commercially available devices are classified and described to offer a valuable tool to summarize their potential combinations to face all the laboratories requirements in terms of analytical applications, robustness, sensitivity, and throughput.

10.
Crit Rev Anal Chem ; 52(7): 1702-1716, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34096409

RESUMO

Formaldehyde (FA) is ubiquitous in the atmospheric environment. It is generally the dominant atmospheric carbonyl compound. Due to its well-known carcinogenicity, FA is a compound that arises the attention in the scientific community. In studies concerning the toxicological effects of FA on humans, animals, and the environment, testing and calibration of air sampling systems and analytical instruments are pivotal. Therefore, the preparation of controllable standard gaseous atmospheres containing FA at levels known with precision and accuracy is essential. This review summarizes the procedures for generating the FA atmosphere, given that operative solutions have been evolving recently. Furthermore, an overview on the available system to collect and store gaseous standard is reported. The progressively implemented FA generation techniques, together with commercially-available instruments, are herein described, classified, and compared.


Assuntos
Formaldeído , Gases , Animais , Humanos
11.
Int J Occup Med Environ Health ; 34(3): 319-338, 2021 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-33236726

RESUMO

The potential carcinogenicity of formaldehyde (FA) has prompted increasing preventive measures in anatomic pathology (AP) laboratories and new strategies aimed at innovating airborne FA monitoring systems. This review provides an updated overview of the most recent improvements in preventive measures, safe practices, and exposure monitoring tools in the FA usage and handling. A computer-based search of scientific and non-scientific sources was performed on PubMed, Web of Science, Google and Google Patents databases, querying the main topics of real-time, in-continuous FA monitoring instruments for sale, and commercially available tools for improving preventive measures in formalin management. In order to simplify the sampling process and to choose a better analytic solution to FA assessment, the main characteristics of each FA monitoring instrument were described. The novel technical tools recently introduced on the global market, aimed at reducing FA emissions in AP laboratories, were summarized. This review is directed at anatomic pathologists to draw their attention to the rapidly growing field of safe formalin practices. A repeated exposure assessment is recommended to evaluate technical changes in air monitoring programs to keep FA emissions low, in compliance with the limit value; thus, evolved monitoring devices are needed. Int J Occup Med Environ Health. 2021;34(3):319-38.


Assuntos
Formaldeído , Exposição Ocupacional , Computadores , Humanos , Laboratórios , Fluxo de Trabalho
12.
Arh Hig Rada Toksikol ; 71(3): 178-189, 2020 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-33074166

RESUMO

The last two decades have been crucial for the assessment of airborne formaldehyde (FA) exposure in healthcare environments due to changes in limits and reference values, definition of carcinogenicity, and new monitoring methods. The aim of this study was to analyse twenty years (1999-2019) of experience in automatic, continuous airborne FA monitoring in the Pathology Laboratory and operating rooms at the Careggi University Hospital, Florence, Italy. These 20 years saw gradual improvements in FA monitoring of exposed employees considered at maximum risk, including improvements in analytical methods of detection and sampling strategies, which came with changes in procedures and workflow operations. In 2019, after the adoption of safe practices, including a closed-circuit system using pre-loaded containers and a vacuum sealing, 94 % of the total measurements (FA concentrations) were lower than 16 µg/m3, and only 6 % ranged from 21 to 75 µg/m3. In the studied work units, the ratio between area and personal readings ranged from 0.9 to 1.0, both for long and short-term sampling. Personal sampling was simplified with a new workstation, which integrated different monitoring systems into an innovative ergonomic armchair equipped with personal sampling devices. Area monitoring was also improved with a real-time, continuous photoacoustic instrument. Over these 20 years, FA exposure significantly dropped, which coincided with optimised histology workflow and implementation of safety practices. For high-throughput screening and cost savings we propose an innovative ergonomic armchair station which allows remote continuous monitoring.


Assuntos
Exposição Ocupacional , Monitoramento Ambiental , Formaldeído , Hospitais , Humanos , Itália , Exposição Ocupacional/prevenção & controle
13.
Med Pr ; 71(5): 519-529, 2020 Sep 24.
Artigo em Inglês | MEDLINE | ID: mdl-32667290

RESUMO

BACKGROUND: Cyclophosphamide (CP) and ifosfamide (IP) contaminations have been detected in hospital environments. This study was conducted to determine if there was any contamination in the spaces (floors and door handles) between the hospital exit and the antineoplastic drugs (ADs) preparation and administration units. At the same time, the authors proposed a new automation of the analytical procedure to considerably decrease the time needed for sample preparation and analysis. MATERIAL AND METHODS: To evaluate the ADs contamination of surfaces, 829 wipe tests were performed in a campaign involving 3 hospitals located in Italy. Sampling was performed using an innovative kit. The levels of ADs were measured in each wipe sample using liquid chromatography/triple quadrupole. RESULTS: On-line solid-phase extraction guarantees the construction of a robust and reproducible analytical method. The CP and IP recoveries from stainless steel, polycarbonate and polyvinyl chloride ranged >80%, and the wipe holders and the automation tested ensured desorption efficiencies close to 100% for both the ADs. Of the 552 wipes taken on the spaces between the hospital exit and the preparation, administration and pharmacy warehouse units, 22 were greater than or equal to the limit of quantification, all adjacent to the administration units. CONCLUSIONS: This study provides an insight into the exposure situation against ADs residues. In order to improve environmental monitoring programs, the authors propose to evaluate the ADs contamination also outside the preparation, administration and pharmacy warehouse units. Med Pr. 2020;71(5):519-29.


Assuntos
Antineoplásicos/análise , Ciclofosfamida/análise , Monitoramento Ambiental/estatística & dados numéricos , Contaminação de Equipamentos , Pessoal de Saúde/estatística & dados numéricos , Hospitais/estatística & dados numéricos , Ifosfamida/análise , Exposição Ocupacional/estatística & dados numéricos , Adulto , Feminino , Humanos , Itália , Masculino , Corpo Clínico Hospitalar , Pessoa de Meia-Idade
14.
Anal Chim Acta ; 1119: 77-100, 2020 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-32439057

RESUMO

This review is an update of a previous review in 2009 and covers publications from 2009 to 2019. The review focuses on experimental design, referred to as the design of experiments (DoE), used in developing bioanalytical solid-phase microextraction (SPME) methods. Characteristics of different SPME approaches are illustrated and critically discussed. The literature selection evidences that two-level full factorial designs, with a limited number of factors (<5), are most frequently used for preliminary factors screening. When applying the response surface methodology for the quantitative assessment of factorial effects, few quadratic models were used. The most popular were the rotatable central composite and Box-Benkhen designs. Models including more than four factors, such as fractional factorial designs (including the Plackett-Burman and Taguchi designs), were rarely used. Definitive screening and D-Optimal designs were not reported anywhere in the literature selection. When examining the diagnostic criteria used to evaluate different model's quality and validity, it was apparent the researchers relied heavily on commercial software for experimental design, analysis, and reporting of the results.


Assuntos
Bioensaio , Projetos de Pesquisa , Microextração em Fase Sólida , Software
15.
Med Lav ; 111(2): 133-150, 2020 Apr 30.
Artigo em Italiano | MEDLINE | ID: mdl-32352427

RESUMO

BACKGROUND: Professional exposure to respirable dust containing crystalline silica is of great interest for the serious lung diseases resulting from exposure. METHODS: During the period 1986-2019, 3611 exposure data to crystalline silica were collected from companies in central Italy. The data were divided and statistically analyzed based on the sampling system (Cyclone Dorr Oliver, CIP 10-R, Cyclone GS3, SKC plastic selector, Cyclone Higgins-Dewell and Cyclone Lippmann) and the ATECO code (code of economic activity, Italian acronym, used to classify companies when they interface with public institutions) of the companies in which they were collected. For each ATECO code, the division was made according to the type of sampling (personal or static) and the descriptive statistics of the data were calculated. RESULTS: Overall, for personal samples, 8.8% of the data exceeds 0.1 mg/m3, 19.6% exceeds 0.05 mg/m3 and 33.8% exceeds 0.025 mg/m3, the limit values set by the EU Directive 2019/130, suggested by the SCOEL and published by ACGIH respectively. The ATECO codes with the highest worker exposure (geometric means 0.067 and 0.069 mg/m3) were 23.31.00 (manufacture of ceramic tiles for floors and walls) and 23.42.00 (manufacture of ceramic sanitary ware), while the lowest exposure is found in 81.29.91 (cleaning and washing of public areas, removal of snow and ice including shedding of sand) with a geometric mean of 0.002 mg/m3. DISCUSSION: Despite the general reduction over time, there are still many sectors in which data are higher than the current occupational exposure limits; especially in these sectors it is necessary to implement the measures to fully assess worker exposure.


Assuntos
Poluentes Ocupacionais do Ar , Bases de Dados Factuais , Exposição Ocupacional , Dióxido de Silício , Poeira , Monitoramento Ambiental , Humanos , Exposição por Inalação , Itália
16.
Clin Lab ; 66(3)2020 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-32162882

RESUMO

BACKGROUND: The case concerns a 30-year-old woman in the 24th week of pregnancy presenting to the medical emergency room with fever and abdominal pain. Urine sediment microscopy revealed the presence of unknown needle-shaped crystals. METHODS: Crystals identification was performed by Fourier-Transform Infrared Spectroscopy coupled to Attenuated Total Reflectance (FTIR-ATR). RESULTS: Amoxicillin crystals were verified with semiquantitative results of 87.7%. CONCLUSIONS: Drug-induced crystalluria is a frequent finding in urine examination and it may be asymptomatic. FTIR spectroscopy is a rapid and specific tool in identification of crystals and could be useful supporting renal disease diagnosis and monitoring drug therapy.


Assuntos
Amoxicilina , Cálculos Urinários , Adulto , Amoxicilina/química , Amoxicilina/urina , Antibacterianos/química , Antibacterianos/urina , Feminino , Humanos , Microscopia , Gravidez , Complicações na Gravidez/diagnóstico , Complicações na Gravidez/urina , Espectroscopia de Infravermelho com Transformada de Fourier , Urinálise , Cálculos Urinários/química , Cálculos Urinários/urina
17.
Int J Occup Med Environ Health ; 33(2): 137-150, 2020 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-32080682

RESUMO

OBJECTIVES: Hydrogen peroxide (HP) accounts for 15% of the total global chemical revenue. According to the National Institute of Occupational Safety and Health, the HP concentration immediately dangerous to human life or health is 75 ppm. Operators exposed to HP should pay attention when choosing the monitoring technique that should be specific and sensitive enough to discriminate the exposure levels from background concentrations. In order to assess the long- and short-term exposure to HP in disinfection processes, the authors compared 6 industrial hygiene monitoring methods to evaluate their efficiency in measuring airborne HP concentrations. MATERIAL AND METHODS: Airborne HP concentrations were evaluated using an on-fiber triphenylphosphine solid-phase microextraction method, and they were compared with those obtained using a 13-mm Swinnex titanium oxysulfate filter holder and 4 portable direct-reading electrochemical sensors. A survey carried out in wood pulp bleaching, food and beverage disinfection processing, and in a hospital department to reduce the risk of spreading nosocomial infections, was performed during routine operations to access the risk of HP occupational exposure. RESULTS: Through the generation of HP gaseous dynamic atmospheres (0.1-85 ppm), the authors evaluated the consistency of the results obtained using the 6 methods described. The monitoring campaigns showed that the increase in HP could be relatively high (until 67 ppm) in food and beverage processing. CONCLUSIONS: In the authors' opinion, the current 8-h time-weighted average limits of 1 ppm for HP do not reflect the actual risk; a short-term exposure limit would, therefore, provide a much better protection. 2020;33(2):137-50.


Assuntos
Poluentes Ocupacionais do Ar/análise , Desinfetantes/análise , Monitoramento Ambiental/métodos , Peróxido de Hidrogênio/análise , Exposição Ocupacional/análise , Humanos , Medição de Risco , Sensibilidade e Especificidade , Níveis Máximos Permitidos
18.
J Mass Spectrom ; 55(7): e4481, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31770470

RESUMO

The determination of urinary S-phenylmercapturic acid (S-PMA) represents the most reliable biomarker to monitor the intake risk of airborne benzene. Recently, the European Chemical Agency deliberated new occupational exposure limits for benzene and recommended an S-PMA biological limit value of 2-µg/g creatinine. This limit is an order of magnitude lower than the previous one, and its determination constitutes a challenge in the analytical field. We developed and validated a method that allows the fully automated and sensitive determination of S-PMA by the use of gas-chromatography negative chemical ionization tandem mass spectrometry in isotopic dilution. For negative chemical ionization, we selected a mixture of 1% isobutane in argon as reactive gas, by studying its chemical ionization mechanism and optimal parameters compared with pure isobutane or pure methane. This gas mixture produces a more abundant signal of the target analyte than isobutane or methane, and it extended the operative lifetime of the ion source, enabling us to start a high-throughput approach of the S-PMA analysis. Moreover, energy-resolved mass spectrometry experiments were carried out to refine the MS/MS analysis conditions, testing nitrogen and argon as collision gases. The method optimization was pursued by a chemometric model by using the experimental design. The quantification limit for S-PMA was 0.10 µg/L. Accuracy (between 98.3% and 99.6%) and precision (ranging from 1.6% to 6.4%) were also evaluated. In conclusion, the newly developed assay represents a powerful tool for the robust, reliable, and sensitive quantification of urinary S-PMA, and because of its automation, it is well suited for application in large environmental and biological monitoring.

19.
Med Lav ; 110(6): 446-458, 2019 Dec 17.
Artigo em Inglês | MEDLINE | ID: mdl-31846449

RESUMO

BACKGROUND: In recent years, under-vacuum sealing (UVS) and containers with formalin encapsulated in the lid have been proposed for the reduction of occupational exposure to airborne formaldehyde (FA) in healthcare environments. OBJECTIVES: We are presenting a study focused on the assessment of FA in hospitals: an automatic sampling system was set, different sampling devices were compared, and the concentration of FA was assessed, following its use in different scenarios. METHODS: Three different devices for sampling/measuring FA were compared. They are based on: 1. silica gel cartridges impregnated with 2,4-dinitrophenylhydrazine (2,4-DNPH); 2. SPME® fiber using O-(2,3,4,5,6-pentafluorobenzyl)hydroxylamine; 3. direct reading commercial instrumentation. Three typical scenarios using FA were investigated: operating theatres where small biopsies are soaked into closed-circuit system 4% FA containers, secretariat of pathology laboratories during the registration of biopsies and pathology laboratories during the filling procedure by UVS and the slicing of biopsies. RESULTS: The automatic sampling system allowed short-, long-, and in continuous-sampling time to measure airborne FA. Different sampling devices provided comparable results when tested to assess FA concentration ranging from 0.020-0.320 ppm in a test chamber, although  the devices based on 2,4-DNPH were  the best in terms of sensitivity and accuracy. The results of 246 samples showed that the FA concentration was less than 0.04 ppm in 91% of the measurements. CONCLUSIONS: The automatic methods efficiently allow sampling and measurement of FA in hospital settings. When using safe practices, the concentration of FA is well below occupational limit values.


Assuntos
Monitoramento Ambiental , Formaldeído , Hospitais , Exposição Ocupacional , Humanos , Laboratórios
20.
Artigo em Inglês | MEDLINE | ID: mdl-31163683

RESUMO

Carbonyl compounds (CCs) are products present both as vapors and as condensed species adsorbed on the carbonaceous particle matter dispersed in the air of urban areas, due to vehicular traffic and human activities. Chronic exposure to CCs is a potential health risk given the toxicity of these chemicals. The present study reports on the measurement of the concentrations of 14 CCs in air as vapors and 2.5 µm fraction PM by the ENVINT GAS08/16 gas/aerosol sampler, a serial sampler that uses annular denuder, as sampling device. The 14 CCs were derivatized during sampling prior to gas-chromatographic separation and multiple detection by mass spectrometry, nitrogen-phosphorus thermionic, electron capture detection. Outdoor air multiple samples were collected in four locations in the urban area of Florence. The results evidenced that formaldehyde, acetaldehyde, and acetone were the more abundant CCs in the studied areas. The data collected was discussed considering the particle to vapor ratio of each CC found. The CCs pollution picture obtained was tentatively related to the nature and intensity of the traffic transiting by the sampling sites. This approach allowed to determine 14 CCs in both concentrated and diluted samples and is proposed as a tool for investigating outdoor and indoor pollution.


Assuntos
Filtros de Ar , Poluentes Atmosféricos/análise , Poluição do Ar em Ambientes Fechados/análise , Aldeídos/análise , Cromatografia Gasosa , Monitoramento Ambiental/métodos , Acetona/análise , Adsorção , Itália , Material Particulado/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...